Connected to Japan Yaskawa inverter: (616G5 PGB2 card, 676G3 PGB card)

Recommended encoder model: CTX600----BZ1-12-24F or CTX1024-----BZ1-12-24F

Working voltage: DC 12V Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z (the Z signal is not used)

Connected to Japan Yaskawa inverter: (616G5 PGX2 card)

Recommended encoder model: CTX1024------BZ1-5L

Working voltage: DC 5V±10% Output form: RS422 long-line drive (LY type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z, -A, -B, -Z

Connected to Japan Fuji inverter: (VG5)

Recommended encoder model: CTX600-----BZ1-12-24F or CTX1024-----BZ1-12-24F

Working voltage: DC 15V Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z (the Z signal is not used)

Connect to Japan Mitsubishi inverter: (FR-A5AP card)

Recommended encoder model: CTX1024------BZ1-5L

Working voltage: DC 5V±10% Output form: RS422 long-line drive (LY type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z, -A, -B, -Z

United Kingdom: Connect to the United Kingdom Inverter: (CT)

Recommended encoder model: CTX1024--------BZ1-5L

Working voltage: DC 5V±10% Output form: RS422 long-line drive (LY type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z, -A, -B, -Z

Germany: Connect with German KEB inverter: (F4)

Recommended encoder model: CTX600----BZ1-12-24F or CTX1024----BZ1-12-24F

Working voltage: DC 5V±10% Output form: RS422 long-line drive (LY type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z, -A, -B, -Z

Connect with German MICO inverter: (340)

Recommended encoder model: CTX1024---BZ1-12-24F

Working voltage: DC ±15V or 15V Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z

Connect with German MICO AC governor: (330)

Recommended encoder model: CTX300----BZ1-12-24F

Working voltage: DC ±15V or 15V Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z

Connect with LENZE inverter:

Recommended encoder model: CTX1024-----BZ1-5L

Working voltage: DC 5V±10% Output form: RS422 long-line drive (LY type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z, -A, -B, -Z

Connect with German Siemens (SIEMENS) vector control inverter: (this machine)

Recommended encoder model: CTX1024-----BZ1-12-24F

Working voltage: DC 15V Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z

Connect with German Siemens (SIEMENS) general controller: (with DT1 interface board)

Recommended encoder model: CTX1024-----BZ1-5L

Working voltage: DC 5V±10% Output form: RS422 long-line drive (LY type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z, -A, -B, -Z

Connect with German Schneider (SCHNEIDER) asynchronous motor inverter:

Recommended encoder model: CTX1024-----BZ1-5L

Working voltage: DC 5V±10% Output form: RS422 long-line drive (LY type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z, -A, -B, -Z

Connect with ABB vector control inverter: (NTAC-02 pulse code)

Recommended encoder model: CTX1024--------BZ1-12-24F

Working voltage: DC 15V or DC 24V Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z

To connect with Denfoss (VLT5000 series) inverter:

Recommended encoder model: CTX1024----------BZ1-12-24F

Working voltage: DC 24V Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z

Connect with American (AB) inverter: (jumper setting 5V)

Recommended encoder model: CTX1024----------BZ1-5L

Working voltage: DC 5V±10% Output form: RS422 long-line drive (LY type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z, -A, -B, -Z

Connect with EMERSON inverter:

Recommended encoder model: CTX1024------BZ1-12-24F

Working voltage: DC 24V Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z

Connect with Beijing Tujie TJ9000Z inverter:

Recommended encoder model: CTX600------BZ1-12-24F or CTX1024-----BZ1-12-24F

Working voltage: DC 12V Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z (the Z signal is not used)

Connect to Guilin Star Technology ST-2000 inverter:

Recommended encoder model: CTX1024------BZ1-12-24F

Working voltage: DC 5V±10% Output form: push-pull output (F type)

The structure can be selected according to the installation requirements. Output signal: A, B, Z


CONTACT

Jinan Kesheng Automation Technology Co., Ltd.

 

Address: A10, Phase I, Times Tiangong Science and Technology Park, Sangzidian Street, Tianqiao District, Jinan City, Shandong Province

Telephone: 0531-85918007

Market: 15106979869 Manager Li

International Department: 15588888229 Manager Zhang

Email: zhang@sdkasei.cn

kasei_gteach@163.com

©2020-2026   Jinan Kesheng Automation Technology Co., Ltd.  SEO  Powered by www.300.cn